17:38 Apr 30, 2023 |
Russian to English translations [PRO] Tech/Engineering - Construction / Civil Engineering | |||||
---|---|---|---|---|---|
|
| ||||
| Selected response from: IrinaN United States Local time: 23:15 | ||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 | blind heat-conducting inclusions |
| ||
3 | partial thermal bridges |
| ||
1 | sp[arate heat-conducting inclusions |
|
Discussion entries: 1 | |
---|---|
blind heat-conducting inclusions Explanation: Filler constructions of modern buildings can contain inside of themselves various elements at which heat conductivity is much more than heat conductivity of the basic layers. These elements, so- called heat-conducting inclusions, are the reason of occurrence of the additional heat flows which are passing through them https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/23... Permits their utilization in thermal calculations of such enclosures containing rectangularly shaped through and blind heat conducting inclusions https://www.researchgate.net/publication/287082770_New_innov... |
| |
Login to enter a peer comment (or grade) |
sp[arate heat-conducting inclusions Explanation: not contiguous, separate heat conductive inclusions. sciencedirect....The software, capable of analyzing 2D temperature fields and generating acceptable results for long window openings, is also widely used. However, the majority of residential and public buildings have windows that are 1.5–2.5 m wide and nearly 2 m high. The application of the 2D analysis to such buildings causes substantial errors. Moreover, 2D calculations cannot take account of the influence of local heat-conducting inclusions, such as beams, bars, anchors, and other similar items. Numerous experimental and theoretical studies, aimed at the improvement of the energy efficiency of buildings, have proven that the numerical analysis of a 3D temperature field can be employed to properly assess the thermal efficiency of a heterogeneous multilayered construction that has heat-conducting inclusions (a 3D numerical method). envelopes..."he energy efficiency of buildings depends on the structural design of their external walls. Envelopes of contemporary buildings represent complex multilayered systems made of structural elements that have different heat transfer parameters. To assess heat losses, one can use heat transfer resistance R, calculated for building envelopes according to t Thermal bridging global assests"" https://www.aisc.org/globalassets/modern-steel/archives/2012... -------------------------------------------------- Note added at 1 hr (2023-04-30 18:42:39 GMT) -------------------------------------------------- links https://www.sciencedirect.com/science/article/abs/pii/S23527... https://www.sciencedirect.com/science/article/abs/pii/S2352710221012973 https://www.aisc.org/globalassets/modern-steel/archives/2012/03/2012v03_thermal_bridging.pdf |
| |
Login to enter a peer comment (or grade) |
partial thermal bridges Explanation: Вот что предлагает канадский институт: http://web.mit.edu/parmstr/Public/NRCan/CanBldgDigests/cbd04... With partial thermal bridges in masonry, where the structural members do not extend through the wall completely, the wall material between the member and the wall surface acts in part as insulation. With the member placed toward the outside (Figure 3e) lateral heat flow in the wall material on the warm side raises the surface temperature over the bridge and TDm is less than TDc . In contrast, with structural member placed toward the inside (Figure 3f) the surface of the bridge is colder and TDm larger than TDc , as it is with exterior insulation. https://www.govinfo.gov/content/pkg/GOVPUB-C13-68587dc9b5c1c... At the right, on the various partial cold bridges with interior insulation, the traces of condensation are practically non-existent. Но ссылок отчаянно мало, несмотря на солидность приведенных, в обоих случаях аж правительственных, и мое чайниковое мнение, что это самое разумное и англозвучащее из всего, что мне удалось накопать. -------------------------------------------------- Note added at 19 hrs (2023-05-01 13:07:17 GMT) -------------------------------------------------- Чаще встречаются insulated t b. Возможно, подразумевается одно и то же. |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.