GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
14:15 Aug 17, 2011 |
Hungarian to English translations [PRO] Tech/Engineering - Petroleum Eng/Sci | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Katalin Horváth McClure United States Local time: 09:48 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 | error volume, under fault volume |
| ||
2 | perturbed volume |
|
Discussion entries: 11 | |
---|---|
perturbed volume Explanation: ld a vitafórumot |
| |
Login to enter a peer comment (or grade) |
error volume, under fault volume Explanation: A vitafórumban írottakkal együtt úgy gondolom, hogy többféle fordítása lehet, attól függően, hogy azokat a bizonyos feltételeket, amelyek mellett ez a tároló (számláló) működik, hogyan nevezzük. Ha "fault conditions", akkor "under fault volume" lehet a megoldás, ha "error conditions", akkor pedig "error volume" vagy esetleg "under error volume". Az alább megadott három anyagban "error volume" a neve. Az első amerikai: "Display of currently measured values of flow rate, flow velocity, sound velocity, indication of system status, display of forward and reverse volume counters as well as forward and reverse error volume counters" http://www.totalflowsupport.com/Manuals-PDF/Totalsonic softw... A második német gyártó, ha jól látom: "Reset Error Volume Counter" http://80.72.135.115/flowsic600/documents/manuals/fr.downloa... A harmadik ugyanaz a gyártó, de más dokumentum: "While the system is in “Error” status, the volumes determined are stored in separate error volume counters. These counters can be reset. Such a reset is recorded in the Custody logbook [1] together with date and time stamp. #5011 “ForwardVolumeErr“ #5013 “ReverseVolumeErr“ ..." http://www.automatyka-przemyslowa.pl/flowsic600/documents/ma... Az "under faulr error" pedig itt található: http://www.dresser.com/documents/RMI/imcw_user_trmnl_hndbk.p... Lásd 51. oldal: "9.1 Clear Occurred Faults A fault is described as a measurement reading that exceeds its acceptable range. This may be caused, for example, by exceeding the stated pressure range of the transducer. When a fault condition occurs, an intuitive indication is displayed on the LCD indicating the nature of the fault (see Table 6 (Fault Code Reference Table)). ... 9.2 Clear Uncorrected Volume Under Fault In all fault conditions, the Uncorrected Under Fault volume register will be activated showing the total number of accumulated uncorrected volume units during the period in which the fault was present. Only faults that affect the correction factor will cause the Uncorrected Under Fault register to be activated. Under these conditions, both the Uncorrected Volume and the Uncorrected Under Fault volume will continue to increment, however the Corrected Volume register will no longer be activated (this register will be re-activated once the fault condition has been cleared)." |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.