Kontaktbrand

Danish translation: brændt kontakt / brændte kontakter

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
German term or phrase:Kontaktbrand
Danish translation:brændt kontakt / brændte kontakter
Entered by: Randi Stenstrop

17:35 Oct 6, 2012
German to Danish translations [PRO]
Tech/Engineering - Electronics / Elect Eng
German term or phrase: Kontaktbrand
Die Schütze und Relais sind auf Kontaktbrand zu überprüfen
Randi Stenstrop
Local time: 10:09
brændt kontakt / brændte kontakter
Explanation:
Udtrykkene 'brændte kontakter' og 'brændte relækontakter' bruges jævnligt blandt fagfolk.
Så oversættelsen kunne starte med noget i retning af: "Undersøg om kontakterne er brændte på......"

Håber det hjælper :-)
Selected response from:

Jens Kaestel
Australia
Local time: 18:09
Grading comment
4 KudoZ points were awarded for this answer



Summary of answers provided
3 +1brændt kontakt / brændte kontakter
Jens Kaestel
1svejsning af kontaktsættene
andres-larsen
Summary of reference entries provided
contact erosion
andres-larsen

  

Answers


1 day 3 hrs   confidence: Answerer confidence 1/5Answerer confidence 1/5
svejsning af kontaktsættene


Explanation:
Kontaktorer og relæer skal kontrolleres for ***svejsning af kontaktsættene***

kilder:

Funktioner
downloads.industrial.omron.eu/.../J150-DA2-04+... -
PDF/Adobe Acrobat - Quick View
***sikringerne forbindes med nominelt 3.15 A max. til sikkerhedsrelæudgangene for at forhindre svejsning af kontaktsættene***. Overholdelse af internationale ...

Kontaktor - et elektromagnetisk relæ
www.molina.dk/kontaktor-et-elektromagnetisk-rel...
***Da kontaktsættenes ben bevæger sig hurtigere og med større kraft i en kontaktor end i et relæ, mindskes risikoen for at kontaktsættet svejses*** ...

Nye motorstartere fra Siemens imødekommer trends i markedet
www.teknikogviden.dk › Artikelarkiv
***Den patenterede løsning banker kontaktsættet åbent, hvis den detekterer, at der er sket eller er ved at ske en svejsning som følge af slid***.

problem med motor - side 2
dk.teknik.el.narkive.com › dk teknik el
***risikerer du at kontaktsættet svejser fast***. Så hvis det er en fast løsning, skal du nok være forberedt på måske at skulle skifte det. :-) Men bare det ...

Solid State Relæ med FET
ingeniordebat.dk › Ingeniørdebat › Konstruktioner
... ***eller en samling neonrør, har det med at brænde fast i kontaktsættet. ... relæer, af kvalitet, er der heller ingen besvær med svejsning , eller slid af kontakter*** .

Kontaktor - Wikipedia, den frie encyklopædi
da.wikipedia.org/wiki/Kontaktor -
Kontaktor
Virkemåde
Når strømmen afbrydes skubber fjederen den ene side af kontaktsættet tilbage i udgangsstillingen, fjederen skubber med en kraft og hastighed så en ***svejsning af kontaktsættene*** undgås.



--------------------------------------------------
Note added at 1 day4 hrs (2012-10-07 21:35:56 GMT)
--------------------------------------------------

yderlige kilde:

SIMATIC NET og HMI - Siemens
www.nwe.siemens.com/.../dk/.../2008_jun.pdf
PDF/Adobe Acrobat - Quick View
...... ***typisk føre til, at kontaktsættet svejser***.


andres-larsen
Venezuela
Local time: 04:09
Native speaker of: Native in EnglishEnglish
PRO pts in category: 32
Login to enter a peer comment (or grade)

1 day 13 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): +1
brændt kontakt / brændte kontakter


Explanation:
Udtrykkene 'brændte kontakter' og 'brændte relækontakter' bruges jævnligt blandt fagfolk.
Så oversættelsen kunne starte med noget i retning af: "Undersøg om kontakterne er brændte på......"

Håber det hjælper :-)

Example sentence(s):
  • Renover selvstarter - se efter om ikke relækontakterne er brændte.
  • Jeg tror du har et relæ med en brændt kontakt.

    Reference: http://dk.fritid.bil.narkive.com/pp4jcoJD/starter-motor-kore...
    Reference: http://www.citronik.dk/jforum/posts/list/15/20644.page
Jens Kaestel
Australia
Local time: 18:09
Specializes in field
Native speaker of: Native in DanishDanish, Native in EnglishEnglish
PRO pts in category: 35

Peer comments on this answer (and responses from the answerer)
agree  andres-larsen: -afbrændt relækontakt- www.billig-scooter.dk › Billig-Scooter.dk › 4-takter - Mine + - kabler brænder
2 days 11 hrs
  -> Tak (vil du kaldes "andres" eller "andres-larsen"?)
Login to enter a peer comment (or grade)




Reference comments


8 hrs
Reference: contact erosion

Reference information:
Automotive, General Purpose and Signal Relays Definitions
relays.te.com/lexicon/
PDF/Adobe Acrobat - Quick View
Contact protection circuits. The effect of an electrical arc causes primarily local ***contact erosion resulting in contact wear and migration*** and as secondary effect ...

High Current AC Break Arc ***Contact Erosion*** - IEEE
ieeexplore.ieee.org/iel5/4694900/4694901/04694914.pdf?...
JJ Shea - 2008 -
pertaining to contact erosion in air at atmospheric pressure including metallic ... ***contact erosion*** during opening of these types of switching devices. There is a ...

***Contact erosion*** in automotive DC relays - Components ... - IEEE
ieeexplore.ieee.org/iel1/33/2551/00076517.pdf?arnumber=76517
CH Leung - 1991 -
I. INTRODUCTION. HERE is a lack of detailed knowledge of how contacts erode. T in low ... properties. Contact bounce causes make operation ***contact erosion***.


--------------------------------------------------
Note added at 8 hrs (2012-10-07 02:31:15 GMT)
--------------------------------------------------

contact pitting:

Relay Contact Life - Electromechanical, Solid State Relays and ...
relays.te.com/appnotes/app_pdfs/13c3236.pdf
PDF/Adobe Acrobat - Quick View
***This pitting may cause premature contact failure. In such an application, it may be desirable to use fine grain silver contacts.*** These contacts are alloyed with ...

Preventative Maintenance
www.andersonpower.com › Products
B. ***Check contact crown surfaces for signs of "pitting" caused by dirt or disengaging connectors under load. One badly pitted contact***, particularly in a connector ...


--------------------------------------------------
Note added at 9 hrs (2012-10-07 03:07:05 GMT)
--------------------------------------------------

contact corrosion:

Application Note 31 - Relays & switches
www.stabilant.com/appnt31h.htm
Why do relay and switch contacts become intermittent? ... either, by themselves, increase contact resistance, or which cause ***corrosion of the contact***. ... there may not be enough current present to keep the contact electrically clean; the very low ...

How to Clean a Starter Relay | eHow.com
www.ehow.com › Car Repair & Maintenance
***Excessive moisture can cause the relay terminals to corrode***. Disconnecting the starter relay and cleaning the corrosion from the contacts can help prevent ...

Lessons In Electric Circuits -- Volume IV (Digital) - Chapter 5
openbookproject.net/electricCircuits/Digital/DIGI_5.html
Relay construction‎: An electric current through a conductor will produce a ... As with switches, ***the " normal" state of a relay's contacts is ... their tendency to corrode*** and sparks may cause problems in some industrial environments.


--------------------------------------------------
Note added at 1 day3 hrs (2012-10-07 20:50:04 GMT)
--------------------------------------------------

Kontaktabbrand = contact erosion:

Anzeigesupport.automation.siemens.com/.../9757-174-0F.... - PDF/Adobe Acrobat
***Check contact erosion*** . ..... Circuit diagrams for tripped signal contact S21 (K06) and S22 (K07) ..... ***Kontaktabbrand überprüfen / Check contact erosion*** ...

***contact erosion > Kontaktabbrand***
www.proz.com/?sp=gloss/term&id=20185733
***contact erosion > Kontaktabbrand***. One translation of the English term contact erosion in German is Kontaktabbrand. Glossary name: EN-DE Dictionary of ...

Leistungsschalter in Einschubtechnik 3WN1 971 AC Circuit ...
support.automation.siemens.com/.../9673-174-0B.... -
PDF/Adobe Acrobat - Quick View
Replacement of main contacts may be carried out at the factory only. Lichtbogenkontakte. Arc contacts. Fig. 19 ***Kontaktabbrand. Contact erosion***. 1 mm . 1,2 mm ...


--------------------------------------------------
Note added at 1 day3 hrs (2012-10-07 20:51:05 GMT)
--------------------------------------------------

sorry:

Kontaktabbrand = contact erosion:

Anzeige
support.automation.siemens.com/.../9757-174-0F.... - PDF/Adobe Acrobat
***Check contact erosion*** . ..... Circuit diagrams for tripped signal contact S21 (K06) and S22 (K07) ..... ***Kontaktabbrand überprüfen / Check contact erosion*** ...

andres-larsen
Venezuela
Native speaker of: Native in EnglishEnglish
PRO pts in category: 32
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search